2 - Automatic bright to dim setting.
Query Command Status String
=Q<pending><CR><LF> Return buffered status state of the MAS3
<pending> = A one digit ASCII value that indicates the pending status commands.
0 - No commands pending.
1 - Power status string is pending.
2 - Channel status string is pending.
3 - Power & Channel status strings are pending.
4 - Lamp Intensity status string is pending.
5 - Power & Lamp status strings are pending.
6 - Channel & Lamp status strings are pending.
7 - Power, Channel & Lamp status strings are pending.
If a ‘X1<CR>’ command has been issued to the MAS3, then the results of the ‘Q?<CR>’ command will always be
0.
If a ‘X0<CR>’ command has been issued and any of the above states change, the command will be buffered await-
ing the proper status request to be issued. This command string returns a status of which MAS3 states have
changed and need to be read by the controller.
Version Status String
=V<version><CR><LF> Return the MAS3 version string.
<version> = A string of ASCII characters that identifies the MAS3 and its version.